The MEGGER DLRO10 bring new standards to low resistance measurement. A fully automatic instrument, selecting the most suitable test current, up to 10 A dc to measure resistance from 0.1 to 2000 on one of seven ranges.
The DLRO10 is built into a strong, lightweight case that is equally at home in the field or in the laboratory. Light enough to be worn around the neck, they are small enough to be taken into areas which were previously too small to access. DLRO10 uses a large, bright 4-1/2-digit LED display.
-
The MOM2 is designed to measure the resistance of circuit breaker contacts, bus-bar joints and other high-current links. This product is designed with safety, ease of use and versatility in mind.
MOM2 uses an ultra capacitor to generate the high output current. The ultra capacitor is able to store a huge amount of energy compared to conventional capacitors and can deliver very high current during the discharge thanks to its very low internal resistance. The microhmmeter can be used anywhere to measure a low resistance value with high accuracy.
With MOM2 it is possible to make measurements according to the DualGroundmethod. This means that the test object will be grounded on both sides throughout the test giving a safer, faster and easier workflow.
-
Poor grounding is dangerous and contributes to unnecessary downtime and increases the risk of equipment failure. The Amprobe GP-2A Earth Ground Resistance Tester provides accurate and reliable measurements for ground resistance and soil resistivity to assure the safety and performance of an electrical system. The GP-2A is complete with PC software that allows the user to download critical recorded measurements and to create professional reports for customers.
-
User-friendly and accurate. Think safety and Amprobe DGC-1000A ground resistance tester second. Use the on-board memory and data logging features to make your work more efficient.
-
Digital, low-value resistance measuring instrument per VDE 0 413 part 4 and EN 61 557 parts 1 and 4.
-
Cost effective, analog insulation tester for electrical systems of up to 1000 V per EN 61 557 parts 1, 2 and 4 (VDE 0413 parts 1 and 4).
-
The analog insulation measuring instrument for quick two-hand operation in accordance with VDE 0413, part 1/2/4, and voltmeter.
-
The METRISO BASE insulation and resistance measuring instruments allow for quick and effective testing of protective measures in accordance with:
-
The METRISO INTRO fulfills all expectations and requirements for getting started with the premium class. Thanks to the included functions, it's especially well-suited for applications involving troubleshooting and inspection of electrical installations, as well as for use in service and industrial applications.
The insulation and resistance measuring instruments allow for quick and effective testing of protective measures in accordance with:
-
Analog high-voltage insulation measuring instrument with the following voltages:
100, 250, 500 and 1000 V (per EN 61 557 part 1) and 1500, 2000, 2500 and 5000 V.
-
Instrument for conventional insulation measurement with selectable voltages of up to 5000 V - Developed and manufactured for all known types of long-term insulation measurement as well
-
The METRISO PRIME 10 insulation tester has been developed for the detection of insulation damage and for protection against electric shock in electrical power supply networks.
The METRISO PRIME 10 insulation tester has been developed for the detection of insulation damage and for protection against electric shock in electrical power supply networks.
It measures resistance up to 40 T with a test voltage of 10 kV in accordance with EN 61557-2. Even in the case of high-frequency interference, absolutely precise measurement results are obtained. Faults can be quickly and easily pinpointed by means of localization with the new pulse control function. Insulation measurements such as PI, DAR, DD, stepped testing (SV), capacitance measurement, temperature measurement and measurement of protective conductor continuity are no problem. These measurement results can be graphically represented at the display immediately.