Page 273 - techequipmentscatalogue2016
P. 273
FL.UKE ®
725 I 725Ex I 726 Multifunction
Process Calibrators
More calibration power!
.. '-.•• 7:;:_ 725/725Ex/726 Multifunction 726 Precision Multifunction
Fluke 725 Process Calibrators Process Calibrator
.. . . ..,,IIlUSlJRE • 1\vo separate channels; measure, source Additional features:
"'" and view process signals simultaneously • More precise measurement and
Fluke 726 • Measure volts, rnA, RTDs, calibration source performance,
thermocouples, frequency, and accuracies of 0.01%
resistance to test sensors and • Transmitter error"10 calculation
transmitters • Memory storage for up to 8 calibration
results
• Source/simulate volts, rnA, • Frequency totalizer and frequency
thermocouples, RTDs, frequency, and pulse train source mode for enhanced
pressure to calibrate transmitters flowmeter testing
• HART mode inserts 250 ohm
• Measure or ·source pressure using any resistor in rnA measure and source
of 29 Fluke 700Pxx Pressure Modules for compatibility with HART
instrumentation
• Source rnA with simultaneous pressure • Integrated pressure switch test allows
measurement to conduct valve and I!P you to capture the set, reset and
tests deadband of a switch
• Custom RTD curves, add calibration
• Perform fast linearity tests with auto constants for certified RID probes for
step and auto ramp features enhanced temperature measurement
• Power transmitters during test using Specifications
24 V loop supply and simultaneous rnA
measurement
• Store frequently-used test setups for
later use
• For 725Ex version see also page 134 and
135
>Pressure pump required
RID eu 10, Ni120; PtlOO (392); rnA
Pt100 (JIS); Pt100, 200, 500, 1000 eremV
terminals)
1 to 1100 Hz
1.0 to 10.0 kHz
10.0 to 15.0 kHz
M = Measure S = Source/Simulate
Unique 726 features a re in bold
725Ex: ATEX cerfified
(Ex ATEX IIIG EEX 1a lIB 171' C)
0.1 "C,0.1 "F toO.2'e
Included Accessories Maximum voltage: 30V Size (HxWxD): 200 mm x 96 mm x 47 mm
Operating temperature: 10' C to 55' C Weight: 0.65 kg
Test Leads, AC175 Test Clips, one pair of Safety: CSA C22.2 No. 1010.1:1992 Battery: Four AA alkaline batteries.
stackable test leads, user's Manuals on EMC: EN50082-1:1992 and EN55022: Battery life: 25 hours typical; battery door
CD-ROM (725Ex also includes CCD control 1994 Class B Warranty: Three years
drawing, Statement of Quality Assurance
Practices, NIST Traceable calibration ern TL220·1 Recommended Accessories
certificate)
SOPK· 27 TPAK 700P27
Ordering Information
Fluke 725 Multifunction Process Calibrator
Fluke 725Ex Intrinsically Safe Multifunction
Process Calibrator
Fluke 726 Precision Multifunction Process
Calibrator
www.tech-equipments.comlsales@tech-equipments.com 267
725 I 725Ex I 726 Multifunction
Process Calibrators
More calibration power!
.. '-.•• 7:;:_ 725/725Ex/726 Multifunction 726 Precision Multifunction
Fluke 725 Process Calibrators Process Calibrator
.. . . ..,,IIlUSlJRE • 1\vo separate channels; measure, source Additional features:
"'" and view process signals simultaneously • More precise measurement and
Fluke 726 • Measure volts, rnA, RTDs, calibration source performance,
thermocouples, frequency, and accuracies of 0.01%
resistance to test sensors and • Transmitter error"10 calculation
transmitters • Memory storage for up to 8 calibration
results
• Source/simulate volts, rnA, • Frequency totalizer and frequency
thermocouples, RTDs, frequency, and pulse train source mode for enhanced
pressure to calibrate transmitters flowmeter testing
• HART mode inserts 250 ohm
• Measure or ·source pressure using any resistor in rnA measure and source
of 29 Fluke 700Pxx Pressure Modules for compatibility with HART
instrumentation
• Source rnA with simultaneous pressure • Integrated pressure switch test allows
measurement to conduct valve and I!P you to capture the set, reset and
tests deadband of a switch
• Custom RTD curves, add calibration
• Perform fast linearity tests with auto constants for certified RID probes for
step and auto ramp features enhanced temperature measurement
• Power transmitters during test using Specifications
24 V loop supply and simultaneous rnA
measurement
• Store frequently-used test setups for
later use
• For 725Ex version see also page 134 and
135
>Pressure pump required
RID eu 10, Ni120; PtlOO (392); rnA
Pt100 (JIS); Pt100, 200, 500, 1000 eremV
terminals)
1 to 1100 Hz
1.0 to 10.0 kHz
10.0 to 15.0 kHz
M = Measure S = Source/Simulate
Unique 726 features a re in bold
725Ex: ATEX cerfified
(Ex ATEX IIIG EEX 1a lIB 171' C)
0.1 "C,0.1 "F toO.2'e
Included Accessories Maximum voltage: 30V Size (HxWxD): 200 mm x 96 mm x 47 mm
Operating temperature: 10' C to 55' C Weight: 0.65 kg
Test Leads, AC175 Test Clips, one pair of Safety: CSA C22.2 No. 1010.1:1992 Battery: Four AA alkaline batteries.
stackable test leads, user's Manuals on EMC: EN50082-1:1992 and EN55022: Battery life: 25 hours typical; battery door
CD-ROM (725Ex also includes CCD control 1994 Class B Warranty: Three years
drawing, Statement of Quality Assurance
Practices, NIST Traceable calibration ern TL220·1 Recommended Accessories
certificate)
SOPK· 27 TPAK 700P27
Ordering Information
Fluke 725 Multifunction Process Calibrator
Fluke 725Ex Intrinsically Safe Multifunction
Process Calibrator
Fluke 726 Precision Multifunction Process
Calibrator
www.tech-equipments.comlsales@tech-equipments.com 267