Page 192 - techequipmentscatalogue2016
P. 192
UKE ®

345 Power Quality
Clamp Meters

The Fluke 345 measures a wide range of • High safety rating: 600V CAT IV / 1000V
electrical parameters for troubleshooting CAT III rated for use at the service

power disturbances in single- and entrance
three-phase electrical loads. With a • aelde current measurements: Clamp-
bright color display to see waveforms
and trends, a low-pass filter to remove on measurement of AC peak and DC
high frequency noise, and a high EMC current up to 2000 A without breaking
immunity design, the Fluke 345 is ideal the circuit
• Harmonic analysis: Analyze, display
for measurements on switching loads
such as variable speed drives, electronic and log harmonics up to the 30th
lighting and UPS systems. harmonic (40th harmonic for 15 Hz to
22 Hz)
• Verify batteries: Direct measurement
of DC ripple (%) for battery and DC
systems

SpeCifications

(Check the Fluke web for detailed specifications)

Fluke 345

'-"...L...._menl 1

DC, DC rms, AC rms All measurements IX and 15 Hz to 1 kHz. w_.f"I!:li
Maximum overload 10,000 Aor JU.~S x freq uency < 400,000. Amps nns is a true rms
Mcasu rin ~ !anRe
Harm onics o- 2000A DCor 1400AC rms -...:~ .7-.· tOlI. . S;lit

All measurements up to 30th harmonic (40th harmonic for 15 Hz to 22 Hz); fr~ucncy ., -45v -2.5" 59.4 "' lO :ll!' Ql,.
range fO : 15 Hz to 22 Hz and 45 Hz to 6S Hz; lac:rms > lOA 'F~. );ft'A ~

VGitace meuumnenl . .J
DC, DC rms, AC rms
~~:'~U~~~:~r~~n~~cl; ~l~ 1 kHz. Maxunum overload 1,000 Vnns. Vo1ts rms lS a

Mcasu rin ~ !anRe 0 - B2S V DC orACnns A ·5
Harm onics ~ , ,-'!- - \ A
All measurements up to 30th harmonic; Frequency range FO : 15 Hz to 22 Hz and 4S Hz
to 6S Hz; Vac:rms > 1V ~,i - ..- ,

~... _ t (_aad""""'_) DC DC rms AC rms T . 22..15",.

Measuring range 0 - 1650 kW DC or 1200 kW ac

~Intuumnent elIDaIt' iUid _ p_ I ~ DC nns. AI:. nns View waveforms fo r equipment
checking and setup
Mcasunng range 0 ·1650 kVA OC or 1200 kVAac
l.VAR ....uumnent (~ aDCI _ _~

Measuring range 0 - 12S0kVAR

~- (oInaIt''''''--p-I 0.3 cap...1.0... 0.3 ind (72.5' cap. .r1'... 72.5' ind)
Measunng range

~ r_

Measuring range 0.3 cap ... 1.0 .. 0.3 ind (72.5' cap ... 0' ... 72.5' ind) Log parameters over time
~ Hour (kWIIJj to track down intermittent faults
Measunng range 4O,oookWHr
~ Included Accessories
Time base 2.5 InS, S ms, 10 ms, 25 ms, SO msldiv
CUrrent management: Soft carrying case, Power Log software,
Ranges 10AI20 AI t,(J A I 100 AI200A/400AllOOOAI2000 A Test probes, Test leads, Alligator clips,
VOltage measurement International AC adapter / battery eliminator,
Ranges 4 VI 10V 120V I 40V I 100 V I 200 V I 400 V I 1000 V Printed English User manual, Multi-language
_ ClUllDlfunctIon measurements DC and 15 Hz ID 1 kHz manual on CD

Ranges 40, 400 and 2000 A Ordering Information
~50 screen shots and over 150,000 individual measurement values
Memory Fluke 345 Power Quality Clamp Meter

Power supply: 1.5 V Alkaline AA MN 1500 or IEC LR6 Display: Color transmissive LCD 320 x 240 pixels
x 6 Battery (70 mm diagonal) with 2 level backlight

Battery life (typical): >10 hours (backlight on full); Digital output: USB interface to a PC

>12 hours (backligh t reduced) Size (HxWxD): 300 mm x 98 mm x 52 mm
Safety: IEC 61010-1 600 VCATIV. 1000V CAT III Jaw opening: 60 mm
(maximum input ~hase-phase 825V rms) double or
reinforced insulanon. pollution degree 2 Jaw capacity: 58 mm diameter
Weight (including batteries): 0.82 kg
Protection: IP40; EN60529
Two Year Warranty
Operating temperature: 0 ·c to 50 ·C

Recommended Accessories

n K29t TP220-t AC220 TPt -t C345