Page 948 - techequipmentscatalogue2016
P. 948
UKE ®

Temperature Calibration
Handheld Temperature Calibrators

These field and bench calibrators source, simulate, and measure pressure, temperature,
and electrical signals with exceptional precision.

712 RTD Process Calibrator 714 Thermocouple .. '-.•• :;;"i'
Calibrator
Delivers outstanding performance, 724 Temperature Calibrator
durability and reliability in a Delivers outstanding performance,
compact. lightweight. and easy- durability and reliability in a Powerful and easy to use to
to-carry tool. compact. lightweight. and easy- measure and source functions for
• Measure temperature from RTD to-carry device. testing and calibrating almost any
• Measure temperature from TC temperature instrument.
probe output • Measure RTDs, thermocouples,
• Simulate RTD output probe output
• Measure additional RTDs using • Simulate TC output ohms, and volts to test sensors
• Calibrate linear TC transmitter and transmitters
ohms measurement function • Source/simulate thermocouples,
• Simulate additional RTDs using with mV source function RTDs, volts, and ohms to cali-
• NIST traceable calibration brate transmitters
ohms source function • Perform fast linearity tests with
• NIST traceable calibration www.nuke.com/114 25 % and 100 % steps
NIST traceable calibration
www.nuke.com/112
www.nuke.com/112

Multifunction Field Temperature Sources

Fast, lightweight and portable with precision temperature control traceable to national standards. Suitable for calibration
of thermocouples, RTDs, PRTs, and other temperature sensors.

9142 Field Metrology Well 9143 Field Metrology Well 9144 Field Metrology Well

Maximizing portability, speed, Maximizing portability, speed, Precision calibration with fast
and functionality for the indus- and functionality for the indus- temperature ramp-up rates for the
trial process environment. trial process environment. industrial process environment.
• - 25°C to 150 °C temperature • 33°C to 350 °C temperature • 50°C to 660°C temperature

range range range
• Display accuracy of ± 0.2 °C • Heat to 660 °C in 15 minutes
• Display accuracy of ± 0.2 °C • Display accuracy from
over full range
over full range • Built-in two - channel readout ± 0. 35 °C at 420°C to
• Built-in two-channel readout ± 0.5 °C at ± 660°C
for PRT, RTD, thermocouple,
for PRT, RTD, thermocouple, 4-20 rnA current • Optional built-in reference
4-20 rnA current • Optional built-in reference thermometer readout
• Optional built-in reference thermometer readout
thermometer readout • Accredited calibration • Accredited calibration
• Accredited calibration
www.nukecal.eu/9143 www.nukecal.eu/9144
www.nukecal.eu/9142
www.tech-equipments.comlsales@tech-equipments.com
942
   943   944   945   946   947   948   949   950   951   952   953