Precision PRTs

High accuracy reference temperature measurements in temperature sources
on the bench or in the field.

5627A Precision 5615 Secondary Reference 5618B Small Diameter
Industrial PRT Temperature Standards Industrial RTD
• Vibration and shock resistant • - 200°C to 420°C
• Calibration accuracy of • Calibrated accuracy ± 0.010 °C Fast response for time-dependent
measurements.
± 0.046 °C at 0 °C at 0 °C • Small diameter sheath, 3.2 mm
• Available with a 90° bend • NVLAP-accredited calibration
• NVLAP-accredited calibration (0.125 inl
included, lab code 200706-0 • Excellent stability
included, lab code 200706-0 • Includes ITS-90 coefficient s
www.f1ukecal.eu/5615 • NVLAP accredited calibration,
www.f1ukecal.eu/5622
lab code 200706-0
5606 Full Immersion PRT
Fully immerse PRT transition www.f1ukecal.eu/561SB
junction inside freezers or
furnaces . 5608/5609/5609-BND
• Transition junction designed Secondary Reference PRTs

to withstand full temperature Drift rate of ± 0.01 °C at 0 °C after
range of probe
• -200°C to 160°C 100 hours at max temperature.
• Calibration accuracy of • 5608: - 200°C to 500°C

± 0.05 °C (full rangel (80 mm minimum immersionl
• 5609: - 200°C to 670°C
• Optional NVLAP accredited
calibration (100 mm minimum immersionl
• Comes with certificate
www.f1ukecal.eu/5606
of compliance - optional
NVLAP-accredited calibration

www.f1ukecal.eu/560S

5622 Fast Response PRTs 5626/5628 Secondary SPRT,
PRT, Temperature Sensors
• Time constants as fast as
0.4 seconds • Range to 661°C
• Meets all ITS-90 requirements
• Small probe diameters ranging
from 0.5 mm to 3.2 mm (four for resistance ratios
models availablel • Rtp drift < 20 mK after 500

• Available as DIN/lEC Class hours at 661°C
A PRTs or with optional Calibrated accuracy of ± 0.006
NVLAP-accredited calibration, °C at 0 °C
lab code 200348- 0 • NVLAP accredited fixed point
calibration
www.f1ukecal.eu/5622
www.f1ukecal.eu/5622

Thermistors 5610/5611/5611T
Secondary Reference
Providing accurate and rugged mperature measurements Thermistor Probes

from a DC to 100 DC. Economical lab-grade therm-
istor probes with low drift
946 susceptibility.
• Short-term accuracy to

± 0.01 DC; one-year drift
< ± 0.01 °C

• 5610: 3.2 mm diameter stain-
less steel sheathed thermistor

• 5611 : 1.5 mm diameter (tipl
silicone coated thermistor

• 561 lT: 3 mm diameter (tipl
PTFE encapsulated thermistor

www.f1ukecal.eu/5610