Page 204 - techequipmentscatalogue2016
P. 204
UKE ®
Norma 4000 I 5000 Power
Analyzer Accessories
Power Phases
The Fluke Norma 4000 Power Analyzer Each plug-in power phase consists of
can be equipped with up to three power a voltage and a current measurement
phases and the Fluke Norma 5000 Power channel. Each measuring channel is
Analyzer can be equipped with up to six available for each basic unit.
power phases. Users can select the power
phase best suited for their application .
Specifications vary depending on the model
of the power phase.
Power Phase Overview
r 3024770 - 30248U l 3024820 3024835 1
Chann el PP42 PPSO I PP54 PP64
Accuracy 0.2% 0.03%
(0.1% rd + 0.1% rQl 0.1% (0.02% rQ + 0.01% ml
Current range 20A 0.05% rd + 0.05% m l OA
Sampling rate 341 kHz 341kHz
Bandwidt h 3 MHz lOA I lOA
3MHz
l MHz I 341 kHz
10 MHz I 3 MHz
Shunts
3024677 The input modules can take up to 10 A Optional shunts for Fluke Norma Series Power
3024689 or 20 A directly or measure current via Analyzers
3024886 wideband precision shunts. The available
range of shunts enables measurements up 32 A Planar Shunt
3024899 to 1500 A and can be used in conjunction
with all of the available input modules.
3024847
3024858 32 A Planar Shunt
3024864 Cables lor 32 A Planar Shunt
3024873 10 ATriaxial Shunt with Cables
3024692 (OJ33 . 0 to 0.5 MHz)
30 ATriaxial Shunt with Cables
10.010 . 0 [0 0.5 MHz)
100 AShunt with Cables 0.0010, 0 to 0.5 MHz)
150 AShunt .... 300 AShunt with Cables 0.1 mO,o to 1 MHz)
500 AShunt with Cables 0.1 mO 0 to 0.2 MHz)
LG Shunt Cables lor High CUrrent Shunts
Cables & Adaptors
3024661
3024704
Printer Accessories www.tech-equipments.comlsales@tech-equipments.com
3024650
198
Norma 4000 I 5000 Power
Analyzer Accessories
Power Phases
The Fluke Norma 4000 Power Analyzer Each plug-in power phase consists of
can be equipped with up to three power a voltage and a current measurement
phases and the Fluke Norma 5000 Power channel. Each measuring channel is
Analyzer can be equipped with up to six available for each basic unit.
power phases. Users can select the power
phase best suited for their application .
Specifications vary depending on the model
of the power phase.
Power Phase Overview
r 3024770 - 30248U l 3024820 3024835 1
Chann el PP42 PPSO I PP54 PP64
Accuracy 0.2% 0.03%
(0.1% rd + 0.1% rQl 0.1% (0.02% rQ + 0.01% ml
Current range 20A 0.05% rd + 0.05% m l OA
Sampling rate 341 kHz 341kHz
Bandwidt h 3 MHz lOA I lOA
3MHz
l MHz I 341 kHz
10 MHz I 3 MHz
Shunts
3024677 The input modules can take up to 10 A Optional shunts for Fluke Norma Series Power
3024689 or 20 A directly or measure current via Analyzers
3024886 wideband precision shunts. The available
range of shunts enables measurements up 32 A Planar Shunt
3024899 to 1500 A and can be used in conjunction
with all of the available input modules.
3024847
3024858 32 A Planar Shunt
3024864 Cables lor 32 A Planar Shunt
3024873 10 ATriaxial Shunt with Cables
3024692 (OJ33 . 0 to 0.5 MHz)
30 ATriaxial Shunt with Cables
10.010 . 0 [0 0.5 MHz)
100 AShunt with Cables 0.0010, 0 to 0.5 MHz)
150 AShunt ....
500 AShunt with Cables 0.1 mO 0 to 0.2 MHz)
LG Shunt Cables lor High CUrrent Shunts
Cables & Adaptors
3024661
3024704
Printer Accessories www.tech-equipments.comlsales@tech-equipments.com
3024650
198