Page 217 - techequipmentscatalogue2016
P. 217
=E=X=T E C HINSTRUMENTS
380820 Universal AC Power Source + AC Power Analyzer
Front (1000W) and Rear (2000W max) universal output sockets for testing
products from 85 to 250VAC, 45 to 65Hz
• Standby Power Measurement for desktop and notebook PCs, LCD 1Vs, AC
adaptor/chargers, and other products that consume power when not in use
• Power Quality Measurement (Watts, Power Factor, Voltage, Current, Harmonics)
• Cost Function calculates cost per day, month, and year
• 99 memory locations for preset voltage and frequency output settings
• Standby and Operation button
• User-programmable Over Current Protection (current limiting)
• Programmable through the built-in RS-232 interface
• Data acquisition mode captures readings to your PC with a user-
programmable sampling rate of 2 to 65,535 seconds
• Complete with AC power cord, RS-232 to USB cable and software; 1 year warranty
SPECIFICATIONS RANGE RESOLUTION BASIC ACCURACY
CE Front Panel 85 to 250V O.IV ±t %
Output Voltage 45 to 65Hz O.OtH ±O.I Hz
Sol\ware Induded Output Frequency 10mWto l 00W O.l mW ±1%
Power 5mA to I.SA O.lmA ±1%
~~ ---:_~ t·'ri"- =,.A AC Current Oto 1 0.00 1 ±0.04
Power Factor
~ Rear Panel 85 to 250V O.IV ±1%
Software included Output Voltage ±O.I Hz
Output Frequency 4S to 6SHz O.OI Hz ±1%
Power ±1%
ACCurrent 100mW to 2000W O.l mW ±0.04
Power Factor ±1.4% (I -10th)
Harmonics (in amps) SmA to l OA O.lmA ±3%
THO
Input Power Source Oto 1 0.001
Dimension! Weight
1 to SOth order O.lmA
0 .0 to 999.9% 0.1%
11OV or 220V; 4S to 6SHz
12 x 10.2 x S.9" (3OS x 260 x 151 mmy 21 .81bs (9.9kg)
ORDERING Universal AC Power Source!Analyzer
380820
380803 True RMS Power Analyzer Datalogger
Compact, battery operated device for analyzing AC power loads - with PC
interface plus datalogging
• Four simultaneous displays of Power, Power Factor or VA, Voltage or Hz, Current
• True RMS Voltage & Current measurements of sine, square, triangular and distorted
waveforms with a crest factor < 5
• Datalogger stores up to 1,012 readings (Single record storage or continuous log)
• Max, Data Hold and Overload Protection
• Battery power provides line isolation
• Plug device to be tested directly into the Power Analyzer
• Sampling (update) rate is 2.5 t imes/second
• Complete with Windows
power cord, 117 VAC adaptor and protective hard case; 1 year warranty
SPECIFICATIONS RANGE RESOLUTION ACCURACY (%RDG) INPUT SIGNAL RANGE
Watt (AC) 200, 2000w O.IW,IW ±0.9% 3OOV, 20A, SO - 400Hz
Power Factor (WatWA) 2S0V, 20A, SO/ 60Hz
0 to 1.00 0.001 ±4 digits ±0.2%
Vo~age (Fuse Protected)
2OOV, 7S0V O.IV, IV ±0.9%
Current
2120A via terminals ±0.9%
Frequency
DimensionslWeight 211 SA via sockets
2kHz, 20MHz 1Hz to 10kHz ±O.S%
13.9xll .8)(3.9" (3S2)(300)(100mm) / 3.61bs (1.6kg)
ORDERING True RMS Power Analyzer Dalalogger
380803 RS-232 to USB Adaptor
USB100
www.tech-equipments.comlsales@tech-equipments.com 211
380820 Universal AC Power Source + AC Power Analyzer
Front (1000W) and Rear (2000W max) universal output sockets for testing
products from 85 to 250VAC, 45 to 65Hz
• Standby Power Measurement for desktop and notebook PCs, LCD 1Vs, AC
adaptor/chargers, and other products that consume power when not in use
• Power Quality Measurement (Watts, Power Factor, Voltage, Current, Harmonics)
• Cost Function calculates cost per day, month, and year
• 99 memory locations for preset voltage and frequency output settings
• Standby and Operation button
• User-programmable Over Current Protection (current limiting)
• Programmable through the built-in RS-232 interface
• Data acquisition mode captures readings to your PC with a user-
programmable sampling rate of 2 to 65,535 seconds
• Complete with AC power cord, RS-232 to USB cable and software; 1 year warranty
SPECIFICATIONS RANGE RESOLUTION BASIC ACCURACY
CE Front Panel 85 to 250V O.IV ±t %
Output Voltage 45 to 65Hz O.OtH ±O.I Hz
Sol\ware Induded Output Frequency 10mWto l 00W O.l mW ±1%
Power 5mA to I.SA O.lmA ±1%
~~ ---:_~ t·'ri"- =,.A AC Current Oto 1 0.00 1 ±0.04
Power Factor
~ Rear Panel 85 to 250V O.IV ±1%
Software included Output Voltage ±O.I Hz
Output Frequency 4S to 6SHz O.OI Hz ±1%
Power ±1%
ACCurrent 100mW to 2000W O.l mW ±0.04
Power Factor ±1.4% (I -10th)
Harmonics (in amps) SmA to l OA O.lmA ±3%
THO
Input Power Source Oto 1 0.001
Dimension! Weight
1 to SOth order O.lmA
0 .0 to 999.9% 0.1%
11OV or 220V; 4S to 6SHz
12 x 10.2 x S.9" (3OS x 260 x 151 mmy 21 .81bs (9.9kg)
ORDERING Universal AC Power Source!Analyzer
380820
380803 True RMS Power Analyzer Datalogger
Compact, battery operated device for analyzing AC power loads - with PC
interface plus datalogging
• Four simultaneous displays of Power, Power Factor or VA, Voltage or Hz, Current
• True RMS Voltage & Current measurements of sine, square, triangular and distorted
waveforms with a crest factor < 5
• Datalogger stores up to 1,012 readings (Single record storage or continuous log)
• Max, Data Hold and Overload Protection
• Battery power provides line isolation
• Plug device to be tested directly into the Power Analyzer
• Sampling (update) rate is 2.5 t imes/second
• Complete with Windows
power cord, 117 VAC adaptor and protective hard case; 1 year warranty
SPECIFICATIONS RANGE RESOLUTION ACCURACY (%RDG) INPUT SIGNAL RANGE
Watt (AC) 200, 2000w O.IW,IW ±0.9% 3OOV, 20A, SO - 400Hz
Power Factor (WatWA) 2S0V, 20A, SO/ 60Hz
0 to 1.00 0.001 ±4 digits ±0.2%
Vo~age (Fuse Protected)
2OOV, 7S0V O.IV, IV ±0.9%
Current
2120A via terminals ±0.9%
Frequency
DimensionslWeight 211 SA via sockets
2kHz, 20MHz 1Hz to 10kHz ±O.S%
13.9xll .8)(3.9" (3S2)(300)(100mm) / 3.61bs (1.6kg)
ORDERING True RMS Power Analyzer Dalalogger
380803 RS-232 to USB Adaptor
USB100
www.tech-equipments.comlsales@tech-equipments.com 211