Page 33 - techequipmentscatalogue2016
P. 33
J}.AMPROBE$

AM-570 Industrial Multimeter

The Amprobe AM-S70 is the best multimeter in its class designed for
professional electricians who need to maintain service or troubleshoot
advanced electrical systems in the most demanding environments. Packed full
of features such as true-rms, dual thermocouples for taking differentiaI
temperature measurements, a low impedance function to detect stray voltage,
and a low pass filter to accurately take measurements on variable frequency
drives, the Amprobe AM-S70 Digital Multimeter allows for quick go-no-go
checks without the need for an additional tool.

• ACIDC Voltage up to 1000V, acldc current, • Peak hold (crest)
resistance, frequency, capacitance, • Relative zero mode
temperature, duty cycle. • Built-in flashlight
• Built-in test leads storage and
• Low Z - to detect stray voltages
"third hand holde....
• Low pass filter for variable frequency drives • Warning against improper test

• VoITect™ Non-contact voltage detection leads connection
• Audible continuity • Auto and manual ranging
• Diode test
• Dual reading backlit LCD display with analog • Auto power off
• Low battery warning
bar graph
• Safety rated: CAT IV 600V,
• Data hold CAT III 1000V
• Maximin memory

AM-S7D DETAILED SPEClnCATIONS

Range Best Accuracy

Resistance 6.000 160.00/600.0/1000 V Yes

AC Current 600.0 mV ±(1 .0% Rdg + 3 LSD) @ 45 Hz to 400 Hz, 0 V to 600 V
DC Current 6.000/60.00/600 .0/1000 V ±(0.5% Rdg + 2 LSD) @ 6 V to 600 V ranges
Frequency
600.0 Ohms ±(1 .0% Rdg + 2 LSD) @ 6 kOhms to 600 kOhms ranges
Capacitance 6.000 I 60.00 1600 .0 kOhms
±(1.2% Rdg + 5 LSD) @ 600 to 6000 ranges, 45 Hz to 400 Hz
6.000 I 60.00 MOhms ±(1 .0% Rdg + 2 LSD) @ 600 to 6000 ranges

600.0 I 6000 ±(0.1% Rdg + 3 LSD)
60.00 mA 1500.0 mA 110.00 A ±(1 .2% Rdg + 30 LSD) @ 5Hz to 2 kHz
±(3.0% Rdg + 5 LSD) @ 600 nF to 60 ranges
600.0 I 6000 _-'--_ of : ±(1 .0% rdg + 12) @ >104 of to 752 of l oe: ±(1.0% rdg + 8) @ >40 °C to 400 °C
60.00 mA 1500.0 mA 110.00 A

60.00 I 600.0 Hz
6.000/60.00/600.0 kHz

6.000/60.00 MHz

10.00% t o 90 .00%

60 .00/600.0 nF
6.000/60.00/600.0 16000

60 .00 mF

-40 of to 1832 of I -40 °C to 1000 °C

Dua l Thermocoup le

INCLUDED ACCESSORIES
I IBatteries (Installed) Test Leads I ITemperature Probe I I IVelao Strap Canying Case User's Manual
Model
K-type probe xl •
AM-SOO AAAx2 • K-type probe xl • •
AM-S10 9V (6F22) xl • K-type probe x2 • •••
AM-S20 9V (6F22) xl • K-type probe x2 •••
AM-S30 9V (6F22) xl • •••
AM-S60 9V (6F22) xl • •••
AM-S70 9V (6F22) xl •

www.tech-equipments.comlsales@tech-equipments.com 27