Page 277 - techequipmentscatalogue2016
P. 277
FL.UKE ®
721 Precision Dual
Pressure Calibrator
Pressure calibration and temperature
measurement for custody transfer
applications
The Fluke 721 Precision Pressure o Ptl00 RID input for temperature
Calibrator with dual isolated pressure
sensors is the ideal tool for gas custody measurement, (probe optional)
transfer applications allowing you to o Measures 4 to 20 rnA signals
take simultaneous static and differential o Internal 24 V loop power supply can
pressure measurements with a single
tool. power a transmitter under test
o Measure up to 30 V DC,
The 721 can be configured by selecting
either a 1.1 bar or 2.48 bar low pressure chec 24 V loop power supplies
sensor then add any of 7 high pressure o Extend pressure measurement range
ranges including 6.9, 20, 24.5,69, 103.4,
200, 345 bar. with connection to external 700 series
pressure modules (29 ranges)
o Ideal for gas flow calibration o Large backlit graphic display can display
(custody transfer) applications up to three inputs simultaneously
o Store five instrument setups for recall
o1Wo isolated, stainless steel, pressure
sensors with 0.025 %accuracy and use
Specifications
(Check the Fluke web for detailed specifications)
Model number I ordering infonnation Range 1 Resolution Aa:uracy Range 2 Resolution Accuracy
F1uke-72I-I60I Dual Sensor Pressure Calibrator -970mbar to 1.1 bar 0.0001 bar 0.025% of range -830mbar to 6.9 bar 0.0001 bar 0.025% of range
F1uke-72I-I603
F1uke-72I-I60S Dual Sensor Pressure Calibrator -970mbar to 1.1 bar 0.0001 bar 0.025% of range -83Ombar to 20 bar 0.001 bar 0.025% of range
F1uke-72I-I6I0
F1uke-72I-I6IS Dual Sensor Pressure Calibrator -970mbar to 1.1 bar 0.0001 bar 0.025% of range -83Ombar to 34.5 bar 0.001 bar 0.025% of range
F1uke-72I-I630
F1uke-72I-I6S0 Dual Sensor Pressure Calibrator -970mbar to 1.1 bar 0.0001 bar 0.025% of range 0.00 bar to 69 bar 0.001 bar 0.025% of range
F1uke-72I-3601
F1uke-721-3603 Dual Sensor Pressure Calibrator -970mbar to 1.1 bar 0.0001 bar 0.025% of range 0.00 bar to 103 bar 0.01 bar 0.025% of range
F1uke-721-360S
F1uke-721-3610 Dual Sensor Pressure Calibrator -970mbar to 1.1 bar 0.0001 bar 0.025% of range 0.00 bar to 200 bar 0.01 bar 0.025% of range
F1uke-721-361S
F1uke-72I-3630 Dual Sensor Pressure Calibrator -970mbar to 1.1 bar 0.0001 bar 0.025% of range 0.00 bar to 345 bar 0.01 bar 0.035% of range
F1uke-72I-36S0
F1uke-720RTD Dual Sensor Pressure Calibrator -970mbar to 2.48 bar 0.0001 bar 0.025% of range -830mbar to 6.9 bar 0.0001 bar 0.025% of range
F1uke-720URTDA
Fluke 71XTrap Dual Sensor Pressure Calibrator -970mbar to 2.48 bar 0.0001 bar 0.025% of range -83Ombar to 20 bar 0.001 bar 0.025% of range
Dual Sensor Pressure Calibrator -970mbar to 2.48 bar 0.0001 bar 0.025% of range -83Ombar to 34.5 bar 0.001 bar 0.025% of range
Dual Sensor Pressure Calibrator -970mbar to 2.48 bar 0.0001 bar 0.025% of range 0.00 bar to 69 bar 0.001 bar 0.025% of range
Dual Sensor Pressure Calibrator -970mbar to 2.48 bar 0.0001 bar 0.025% of range 0.00 bar to 103.4 bar 0.01 bar 0.025% of range
Dual Sensor Pressure Calibrator -970mbar to 2.48 bar 0.0001 bar 0.025% of range 0.00 bar to 200 bar 0.01 bar 0.025% of range
Dual Sensor Pressure Calibrator -970mbar to 2.48 bar 0.0001 bar 0.025% of range 0.00 bar to 345 bar 0.01 bar 0.035% of range
RTD probe for Fluke 721 and 719Pro
UniversallITD adapter for Fluke 721 and 719Pro
Liquid and dirt trap for Fluke 718. 719 and 719Pro
Supported Pressure Units; psi. in. H,O(4' C). £Me: EN50082-1:1992 and EN55022:1994 Class B
in . H,O(20' C). cm H,O(4' C). cm H,O(20' C).
bar m Bar. kPa. inHg. m m Hg. kg/cm' Fluke 721: All media compatible with 31655
Max Voltage: 30V Battery: 4 standard AA alkaline batteries
Operating temperature: -10' C to 50' C Three year warranty
Safety: C5A C22.2 No. 1010.1:1992
www.tech-equipments.comlsales@tech-equipments.com 271
721 Precision Dual
Pressure Calibrator
Pressure calibration and temperature
measurement for custody transfer
applications
The Fluke 721 Precision Pressure o Ptl00 RID input for temperature
Calibrator with dual isolated pressure
sensors is the ideal tool for gas custody measurement, (probe optional)
transfer applications allowing you to o Measures 4 to 20 rnA signals
take simultaneous static and differential o Internal 24 V loop power supply can
pressure measurements with a single
tool. power a transmitter under test
o Measure up to 30 V DC,
The 721 can be configured by selecting
either a 1.1 bar or 2.48 bar low pressure chec 24 V loop power supplies
sensor then add any of 7 high pressure o Extend pressure measurement range
ranges including 6.9, 20, 24.5,69, 103.4,
200, 345 bar. with connection to external 700 series
pressure modules (29 ranges)
o Ideal for gas flow calibration o Large backlit graphic display can display
(custody transfer) applications up to three inputs simultaneously
o Store five instrument setups for recall
o1Wo isolated, stainless steel, pressure
sensors with 0.025 %accuracy and use
Specifications
(Check the Fluke web for detailed specifications)
Model number I ordering infonnation Range 1 Resolution Aa:uracy Range 2 Resolution Accuracy
F1uke-72I-I60I Dual Sensor Pressure Calibrator -970mbar to 1.1 bar 0.0001 bar 0.025% of range -830mbar to 6.9 bar 0.0001 bar 0.025% of range
F1uke-72I-I603
F1uke-72I-I60S Dual Sensor Pressure Calibrator -970mbar to 1.1 bar 0.0001 bar 0.025% of range -83Ombar to 20 bar 0.001 bar 0.025% of range
F1uke-72I-I6I0
F1uke-72I-I6IS Dual Sensor Pressure Calibrator -970mbar to 1.1 bar 0.0001 bar 0.025% of range -83Ombar to 34.5 bar 0.001 bar 0.025% of range
F1uke-72I-I630
F1uke-72I-I6S0 Dual Sensor Pressure Calibrator -970mbar to 1.1 bar 0.0001 bar 0.025% of range 0.00 bar to 69 bar 0.001 bar 0.025% of range
F1uke-72I-3601
F1uke-721-3603 Dual Sensor Pressure Calibrator -970mbar to 1.1 bar 0.0001 bar 0.025% of range 0.00 bar to 103 bar 0.01 bar 0.025% of range
F1uke-721-360S
F1uke-721-3610 Dual Sensor Pressure Calibrator -970mbar to 1.1 bar 0.0001 bar 0.025% of range 0.00 bar to 200 bar 0.01 bar 0.025% of range
F1uke-721-361S
F1uke-72I-3630 Dual Sensor Pressure Calibrator -970mbar to 1.1 bar 0.0001 bar 0.025% of range 0.00 bar to 345 bar 0.01 bar 0.035% of range
F1uke-72I-36S0
F1uke-720RTD Dual Sensor Pressure Calibrator -970mbar to 2.48 bar 0.0001 bar 0.025% of range -830mbar to 6.9 bar 0.0001 bar 0.025% of range
F1uke-720URTDA
Fluke 71XTrap Dual Sensor Pressure Calibrator -970mbar to 2.48 bar 0.0001 bar 0.025% of range -83Ombar to 20 bar 0.001 bar 0.025% of range
Dual Sensor Pressure Calibrator -970mbar to 2.48 bar 0.0001 bar 0.025% of range -83Ombar to 34.5 bar 0.001 bar 0.025% of range
Dual Sensor Pressure Calibrator -970mbar to 2.48 bar 0.0001 bar 0.025% of range 0.00 bar to 69 bar 0.001 bar 0.025% of range
Dual Sensor Pressure Calibrator -970mbar to 2.48 bar 0.0001 bar 0.025% of range 0.00 bar to 103.4 bar 0.01 bar 0.025% of range
Dual Sensor Pressure Calibrator -970mbar to 2.48 bar 0.0001 bar 0.025% of range 0.00 bar to 200 bar 0.01 bar 0.025% of range
Dual Sensor Pressure Calibrator -970mbar to 2.48 bar 0.0001 bar 0.025% of range 0.00 bar to 345 bar 0.01 bar 0.035% of range
RTD probe for Fluke 721 and 719Pro
UniversallITD adapter for Fluke 721 and 719Pro
Liquid and dirt trap for Fluke 718. 719 and 719Pro
Supported Pressure Units; psi. in. H,O(4' C). £Me: EN50082-1:1992 and EN55022:1994 Class B
in . H,O(20' C). cm H,O(4' C). cm H,O(20' C).
bar m Bar. kPa. inHg. m m Hg. kg/cm' Fluke 721: All media compatible with 31655
Max Voltage: 30V Battery: 4 standard AA alkaline batteries
Operating temperature: -10' C to 50' C Three year warranty
Safety: C5A C22.2 No. 1010.1:1992
www.tech-equipments.comlsales@tech-equipments.com 271