Page 634 - techequipmentscatalogue2016
P. 634
0-T Series (Indoor)
Silicone Rubber Indoor Tubular Termination Kits with High-K Stress Relief
Kit Selection Table
NOTE: Final Determination Factor is cable insulation diameter.
Conductor Size Range (AWG & kcmiQ
8 kV 15 kV 25128 kV
Primary Insulation I I I IJacket I
Kit Number 0.0. Range 0.0. Range 5 kV *35 kV
7693-T-150 0.72" - 1.29" 1.04" - 1.60" 300 - 500 250 - 500 2/0 - 300 2 - 4/0 2 - 210
7695-T-150 (18,3 - 32,8 mm) (35 -70 mm')
7696-T-150 (26,4 - 40,6 mm) (70 - 150 mm~ (35 - 120 mm~
1.05" - 1.80" 3/0 - 600
(26,7 - 45,7 mm) 1.39" - 2.40" 700 - 1500 600 -1250 500 -1000 250 - 800 (95 - 325 mm')
1.53" - 2.32" (35,3 - 61,0 mm) (240 - 500 mm') (150 - 400 mm') 700 - 1500
(38,9 - 58,9 mm) (400 - 725 mm~
1.84" - 2.80" 1750 - 2000 1500 - 2000 1250 - 2000 900 - 1750
(46,7 -71 ,1 mm) (625 - 1000 mm') (500 - 800 mm')
*The 150 kV impulse level meets the impulse requirements for 35 kV class equipment where indoor terminations are used.
Table 1
7620-S Series (Outdoor)
Silicone Rubber Skirted Termination Kit with High-K Stress Relief for Tape
Shield, Wire Shield and UniShield® Cable 7622-S-2, 7622-S-2(L)
Kit Selection Tables
NOTE: Final Determination Factor is cable insulation diameter.
7622-S-2(L) QL2-A-2-250
628 www.tech-equipments.comlsales@tech-equipments.com
Silicone Rubber Indoor Tubular Termination Kits with High-K Stress Relief
Kit Selection Table
NOTE: Final Determination Factor is cable insulation diameter.
Conductor Size Range (AWG & kcmiQ
8 kV 15 kV 25128 kV
Primary Insulation I I I IJacket I
Kit Number 0.0. Range 0.0. Range 5 kV *35 kV
7693-T-150 0.72" - 1.29" 1.04" - 1.60" 300 - 500 250 - 500 2/0 - 300 2 - 4/0 2 - 210
7695-T-150 (18,3 - 32,8 mm) (35 -70 mm')
7696-T-150 (26,4 - 40,6 mm) (70 - 150 mm~ (35 - 120 mm~
1.05" - 1.80" 3/0 - 600
(26,7 - 45,7 mm) 1.39" - 2.40" 700 - 1500 600 -1250 500 -1000 250 - 800 (95 - 325 mm')
1.53" - 2.32" (35,3 - 61,0 mm) (240 - 500 mm') (150 - 400 mm') 700 - 1500
(38,9 - 58,9 mm) (400 - 725 mm~
1.84" - 2.80" 1750 - 2000 1500 - 2000 1250 - 2000 900 - 1750
(46,7 -71 ,1 mm) (625 - 1000 mm') (500 - 800 mm')
*The 150 kV impulse level meets the impulse requirements for 35 kV class equipment where indoor terminations are used.
Table 1
7620-S Series (Outdoor)
Silicone Rubber Skirted Termination Kit with High-K Stress Relief for Tape
Shield, Wire Shield and UniShield® Cable 7622-S-2, 7622-S-2(L)
Kit Selection Tables
NOTE: Final Determination Factor is cable insulation diameter.
7622-S-2(L) QL2-A-2-250